Train communication network (TCN)

MVB converters

MVB converters mediate the conversion of various communication lines to an MVB line. Converters can be used to connect units with Ethernet or CAN communication lines to the MVB line. Communication transfer is ensured in both directions.

  • MVB according to IEC 61375-3-1 standard
  • extended temperature range of operating temperatures -40 °C to 70 °C
  • construction according to EN 50155

MVB interface

1 × (doubled line)

Class MVB

class 1 / 2 / 4 without MD / 4

Interface type

EMD / ESD

Connectors

2× D-sub DE-9 (chaining)

Communication speed

1.5 Mbps ± 0.01%

Communication interface 2

Ethernet / CAN

Power supply

24 In ss. (-30% to +25%)

Mass

0.86 kg

Cover

IP20

Construction

on the base plate, 2x hole ø 6 mm

Operating temperature

-40°C to 70°C

Norms

EN 50155, EN 50121-3-2, EN 61373, EN 60068-2-1, EN 60068-2-2, IEC 61375-3-1

Available types:

RB-RTM/2B011

MVB / Ethernet gateway; MVB EMD physical interface

RB-RTM/2E011

MVB / Ethernet gateway; MVB OGF physical interface

RB-RTM/2G011

MVB / Ethernet gateway; MVB ESD physical interface

RB-RTM/2A011

MVB / CAN gateway; optionally MVB EMD/ESD/OGF physical interface

RB-RTM/4B011

MVB EMD (Class 4) / Ethernet